ICPC logo

Sloped End Section Details

Cretex reinforced concrete pipe sloped ends are used to obtain smooth outlets in a pipe line.

Sloped End Section Design Data

Sloped End Section Side View

Sloped End Section End View

PIPE
SIZE
T A B SLOPE BARREL L SECTION 1 SECTION 2 SECTION 3
LENGTH WEIGHT LENGTH WEIGHT LENGTH WEIGHT
24" 3" 6 7/8" 5 1/8" 5'-0" 3'-0" 8'-0" 8'-0" 1600 - - - -
30" 3 1/2" 9 5/8" 5 7/8" 6'-0" 2'-0" 8'-0" 8'-0" 2150 - - - -
36" 4" 12" 6 1/4" 7'-3" 1'-3" 8'-6" 8'-6" 2950 - - - -
42" 4 1/2" 12" 6 7/8" 9'-2 1/2" 2'-9 1/2" 12'-0" 6'-0" 3500 6'-0" 2150 - -
48" 5" 12" 7 3/8" 11'-2 1/2" 2'-9 1/2" 14'-0" 8'-0" 5550 6'-0" 2500 - -
54" 5 1/2" 12" 7 7/8" 13'-2 1/2" 2'-9 1/2" 16'-0" 8'-0" 6950 8'-0" 4100 - -
60" 6" 12" 8 3/8" 15'-2 1/2" 2'-9 1/2" 18'-0" 6'-0" 6800 6'-0" 4650 6'-0" 3300
66" 6 1/2" 12" 8 7/8" 17'-2 1/2" 2'-9 1/2" 20'-0" 8'-0" 10200 6'-0" 5200 6'-0" 3800
72" 7" 12" 9 3/8" 19'-2 1/2" 2'-9 1/2" 22'-0" 8'-0" 12050 8'-0" 8050 6'-0" 4250
 