ICPC logo

Gasketed Pipe Design

CX-4 joints meet the strict requirements of ASTM Specifications C361, Reinforced Concrete Low-Head Pressure Pipe and C443, Joints for Circular Concrete Sewer and Culvert Pipe, using flexible, watertight rubber gaskets. It also meets the requirements of the Bureau of Reclamation specification for the type R-4 joint and is ideally suited for reliable yet economical transmission of water at internal pressure heads of up to 125 feet. The CX-4 joint is easily assembled due to the smoothly curved bell and slightly sloping surfaces. Precision tolerances are obtained from precisely machined heavy duty rings that remain on the bell and spigot until the concrete has pemanently set insuring close tolerance joint clearances and a uniform gasket compression. The enlarged and substantial spigot provide extra strength to the joint. Pipe may be vacuum or air tested in-plant under our Quality Control Program.


12"-66" Sizes

72"-120" Sizes
PIPE
SIZE
WALL B AND C WALL B WALL C
WATER AREA J JOINT B C S T A WT./FT. T A WT./FT.
INCHES SQ. FT. INCHES INCHES INCHES INCHES INCHES INCHES LBS. INCHES INCHES LBS.
12 0.8 3 5/8 1.67 2.39 0.06 2 2 100 3 1 150
15 1.2 3 5/8 1.92 2.58 0.06 2 1/4 2 3/16 135 3 1 7/16 185
18 1.8 3 5/8 2.10 2.83 0.06 2 1/2 2 3/8 180 3 1/4 1 5/8 235
21 2.4 3 7/8 2.36 3.01 0.06 2 3/4 2 9/16 230 3 1/2 1 13/16 295
24 3.1 3 7/8 2.55 3.26 0.06 3 2 3/4 290 3 3/4 2 360
27 4.0 4 2.80 3.26 0.06 3 1/4 2 3/4 350 4 2 425
30 4.9 4 3.05 3.26 0.06 3 1/2 2 3/4 415 4 1/4 2 500
33 5.9 4 1/8 3.31 3.39 0.06 3 3/4 2 7/8 490 4 1/2 2 1/8 580
36 7.1 4 1/8 3.56 3.64 0.06 4 3 1/8 570 4 3/4 2 3/8 665
42 9.6 4 5/8 4.09 4.24 0.07 4 1/2 3 3/4 755 5 1/4 3 865
48 12.6 4 3/4 4.60 4.61 0.07 5 4 1/8 965 5 3/4 3 3/8 1085
54 15.9 5 4.60 4.62 0.07 5 1/2 3 5/8 1170 6 1/4 2 7/8 1310
60 19.6 5 4.60 4.62 0.07 6 3 1/8 1395 6 3/4 2 3/8 1550
66 23.8 5 4.60 4.75 0.07 6 1/2 2 3/4 1645 7 1/4 2 1815
*72 28.3 5 1/4 3.70 4.13 0.09 7 N/A 1860 7 3/4 N/A 2060
*78 33.2 5 1/4 4.20 4.13 0.09 7 1/2 N/A 2160 8 1/4 N/A 2380
84 38.5 5 1/4 3.83 4.25 0.09 8 N/A 2480 SPECIAL DESIGN
90 44.2 5 1/4 3.95 4.63 0.09 8 1/2 N/A 2820 SPECIAL DESIGN
96 50.3 5 1/4 4.20 4.88 0.09 9 N/A 3190 SPECIAL DESIGN
108 63.6 6 3/8 4.26 5.85 0.13 10 N/A 4030 SPECIAL DESIGN
120 78.5 6 3/8 4.76 5.51 0.13 11 N/A 4800 SPECIAL DESIGN

* Only C-Wall design meets the requirements of the Bureau of Reclamation

 