Standard Installations and Fill Height Tables |
|
Construction
Sequence: 1. Place bedding material to grade. Do not compact bedding under pipe invert. (Do/3) 2. Install pipe to line and grade. 3. Compact outer bedding. 4. Place and compact the haunch area up to the springline. 5. Complete backfill according to specifications. |
||
|
|
||
|
Notes: |
|
Maximum
Overfill (ft.) HS20 Live Loads Included |
|||||||||||||||||||||
|
Pipe
Size (Inches) |
Installation Type 2 | Installation Type 3 | Installation Type 4 | ||||||||||||||||||
| Pipe Class | Pipe Class | Pipe Class | |||||||||||||||||||
| 2 | 3 | 4 | 5 | 40D | 50D | 60D | 2 | 3 | 4 | 5 | 40D | 50D | 60D | 2 | 3 | 4 | 5 | 40D | 50D | 60D | |
| 12-15 | - | - | - | 42 | 50 | * | * | - | - | - | 33 | 44 | 50 | * | - | - | - | 22 | 31 | 38 | 45 |
| 18-33 | - | 19 | 28 | 42 | 50 | * | * | - | 14 | 21 | 33 | 44 | 50 | * | - | 10 | 15 | 23 | 31 | 39 | 47 |
| 36-66 | 13 | 18 | 27 | 41 | 50 | * | * | 9 | 13 | 21 | 32 | 44 | 50 | * | 7 | 9 | 15 | 23 | 32 | 40 | 47 |
| 72-120 | 12 | 18 | 26 | 40 | 50 | * | * | 9 | 13 | 20 | 32 | 43 | 50 | * | 6 | 8 | 15 | 23 | 32 | 40 | 47 |
| * Fill heights determined upon request. Please contact your state office for more information. | |||||||||||||||||||||
|
DISCLAIMER The successful application and use of the Cretex Fill Height Tables is dependent on the application of skilled engineering judgment supplied by the pipeline designer. The tabulated fill height values have been selected by the Cretex Company based on standard pipe designs with verifiable test strengths. Pipelines must be installed according to details on this drawing and those specified in the American Association of Highway and Transportation Officials’ (AASHTO), LRFD Bridge Design Specifications. The designer must be familiar with local soil types and pipe installation methods before making the proper selection of concrete pipe strength. |
|||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||